The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features.


Warranty

This product is covered by a 5 years limited warranty

Delivery and Shipping

Orders are shipped within 2 business days. If a problem prevents us from shipping your order within this time, we will notify you.

Depending on your delivery location, transit time will vary from 1 day to 5 days

Note for US and Internationnal buyers: the customer is responsible for paying any import costs to the shipping carrier, such as duties, import taxes, or brokerage/disbursement fees which may apply upon delivery.

Victron Energy MultiPlus 24/2000/50-50 120V VE.Bus (UL Certified) Inverter/Charger at a glance

  • DC Input Voltage

    24V

  • AC Output Voltage

    120V

  • Continuous Power

    1600W at 25°C

  • Peak Power (3 sec.)

    3500W

  • DC Charge Current

    50A

  • Number of AC Input

    1 X 120V

  • Transfert Switch

    50A

  • Number of AC Output

    2 X 120V

  • Dimensions (H x W x D)

    19.9 X 9.3 X 5.8 in
    506 X 236 X 147 mm

  • Weight

    34.2 lbs / 15.5 kg

  • Communication Port(s)

    VE.Bus

Other available models of Victron Multiplus Inverters/Chargers

A table comparing the facets of 5 products
Facet
Victron Energy CMP122200102 Multiplus 12v 2000 120v Compact inverter/charger - front
Victron Energy MultiPlus Compact 12/2000/80-50 120V VE.Bus (UL Certified) Inverter/Charger
View details
Victron Energy PMP122200102 MultiPlus 12/2000/80-50 120V VE.Bus (UL) inverter/charger - front
Victron Energy MultiPlus 12/2000/80-50 120V VE.Bus (UL Certified) Inverter/Charger
View details
Victron Energy PMP242200102 MultiPlus 24/2000/50-50 120V VE.Bus (UL) inverter/charger - front
Victron Energy MultiPlus 24/2000/50-50 120V VE.Bus (UL Certified) Inverter/Charger
View details
Victron EnergyPMP122301102 Multiplus 12/3000 inverter/charger - front
Victron Energy MultiPlus 12/3000/120-50 120V VE.Bus (UL Certified) Inverter/Charger
View details
Victron Energy PMP242301102 Multiplus 24/3000 inverter/charger - front
Victron Energy MultiPlus 24/3000/70-50 120V VE.Bus (UL Certified) Inverter/Charger
View details
Price
Price
$1,287.87 CAD
$1,227.35 CAD
$1,118.41 CAD
$1,664.30 CAD
$1,687.30 CAD
DC Input Voltage
DC Input Voltage
12V
12V
24V
12V
24V
AC Output Voltage
AC Output Voltage
120V
120V
120V
120V
120V
Continuous Power
Continuous Power
1600W at 25°C
1600W at 25°C
1600W at 25°C
2400W at 25°C
2400W at 25°C
Peak Power
Peak Power
4000W
3500W
3500W
6000W
6000W
DC Charge Current
DC Charge Current
80A
80A
50A
120A
70A
Number of AC Input
Number of AC Input
1 X 120V
1 X 120V
1 X 120V
1 X 120V
1 X 120V
Transfer Switch
Transfer Switch
50A
50A
50A
50A
50A
Number of AC Output
Number of AC Output
1 X 120V
2 X 120V
2 X 120V
2 X 120V
2 X 120V
Dimensions (H x W x D)
Dimensions (H x W x D)
20.5 X 10.0 X 5.0 in
520 X 255 X 125 mm
19.9 X 9.3 X 5.8 in
506 X 236 X 147 mm
19.9 X 9.3 X 5.8 in
506 X 236 X 147 mm
14.3 X 10.2 X 8.6 in
362 X 258 X 218 mm
14.3 X 10.2 X 8.6 in
362 X 258 X 218 mm
Weight
Weight
25 lbs / 13 kg
34.2 lbs / 15.5 kg
34.2 lbs / 15.5 kg
40 lbs / 19 kg
40 lbs / 19 kg
Communication Port(s)
Communication Port(s)
VE.Bus
VE.Bus
VE.Bus
VE.Bus
VE.Bus

Victron Energy MultiPlus 24/2000/50-50 120V VE.Bus (UL Certified) Inverter/Charger

General

Multifunctional


The MultiPlus gets its name from the multiple functions it can perform. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single enclosure. Beside these primary functions, however, the MultiPlus has several advanced features that provide a range of new applications as outlined
below.

Uninterrupted AC power

In the event of a grid failure, or shore or generator power being disconnected, the inverter within the MultiPlus is automatically activated and takes over supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and
other electronic equipment will continue to operate without disruption.

Parallel and 3-phase operation capability

Up to 6 inverters can operate in parallel to achieve higher power output.

Operation in 3-phase configuration is also possible.

PowerControl – Dealing with limited generator or shore side power

With a Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

PowerAssist – Boosting the capacity of shore or generator power

This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus Compact to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, it is possible to reduce the size of generator needed or conversely enable more to be achieved from the typically limited shore connection. When the load reduces, the spare power is used to recharge the battery.

Programmable relay

The MultiPlus is equipped with a programmable relay that by default is set as an alarm relay. The relay can be programmed for all kinds of other applications however, for example as a starter relay for a generator.

Battery charger

Adaptive 4-stage charging characteristics: bulk – absorption – float – storage

The microprocessor-driven adaptive battery management system can be adjusted for various types of batteries. The adaptive function automatically adapts the charging process to battery use.

The right amount of charge: variable absorption time

In the event of slight battery discharge, absorption is kept short to prevent overcharging and excessive gas formation. After deep discharging, the absorption time is automatically extended in order to fully charge the battery.

Preventing damage due to excessive gassing: the
Battery Safe mode


If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, damage due to excessive gassing will be prevented by automatically limiting the rate of voltage increase once the gassing voltage has been reached.

Less maintenance and aging when the battery is not in use: the Storage mode

The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the Storage mode float voltage is reduced to 2,2V/cell (13,2V for 12V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

Two DC outputs for charging two batteries

The main DC terminal can supply the full output current. The second output, intended for charging a starter battery, is limited to 1A and has a slightly lower output voltage.

Increasing service life of the battery: temperature compensation

The temperature sensor (supplied with the product) serves to reduce charging voltage when battery temperature rises. This is particularly important for maintenance-free batteries, which could otherwise dry out by overcharging.

More on batteries and charging

Our book ‘Energy Unlimited’ offers further information on batteries and battery charging, and is available free of charge on our website (see www.victronenergy.com → Support & Downloads’ → General Technical Information). For more information on adaptive charging, please also refer to the General Technical Information on our website.

Self consumption – solar energy storage systems

When the MultiPlus is used in a configuration in which it will feed back energy to the grid it is required to enable grid code compliance by selecting the grid code country setting with the VEConfigure tool.

Once set, a password will be required to disable grid code compliance or change grid code related parameters.

If the local grid code is not supported by the MultiPlus an external certified interface device should be used to connect the MultiPlus to the grid.

Special note for Australian customers: IEC62109.1 certification and CEC approval for off-grid use does NOT imply approval for grid-interactive installations. Additional certification to IEC 62109.2 and AS 4777.2.2015 are required before grid-interactive systems can be implemented. Please check Clean Energy Council website for current approvals.

How to reduce the power consumption of an inverter in standby?

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)