Take advantage of our expertise
Radiant heating
Saint-Colomban
House and garage
Client : Residential clients
Context
In the summer of 2021, Ecosolaris was mandated by a couple to design and install a hydronic radiant floor system in their residence under construction.
Needs
Heat the concrete slab of the residence:
House: 2075 sq. ft. with 6 thermostats
Garage: 840 ft2 with 1 thermostat
Installation
PEX tubing was attached directly to the wire mesh over an urethane insulation
One of the manifolds is deported to a closet in the center of the house to to obtain a better heat distribution.
Floor finish
In the house, ceramic tiles were selected as the floor covering
In the garage, no covering was installed over the concrete
Mechanical room components
1 X Thermo 2000 24kW BTH Ultra Electric boiler
2 X Wilo S-21 circulating pump
1 X Manifold Ecosolaris 5 circuits (Garage)
1 X Manifold Ecosolaris 12 circuits (House)
7 X Thermostats Sinopé TH1400ZB with floor sensor
1 Caleffi ZSR101 control box (garage)
1 Caleffi ZVR106 control box (house)
12 X Ecosolaris actuators